| InQor DC/DC Converters | ||
| SynQor’s ruggedized dc/dc converters... the power behind industry |
| Quarter-Brick | ||
| Pin | Name | Function |
| 1 | Vin(+) | Positive input voltage |
| 2 | ON/OFF | TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. |
| 3 | Vin(–) | Negative input voltage |
| 4 | Vout(–) | Negative output voltage |
| 5 | SENSE(–) | Negative remote sense1 |
| 6 | TRIM | Output voltage trim2 |
| 7 | SENSE(+) | Positive remote sense3 |
| 8 | Vout(+) | Positive output voltage |
Half-Brick (Peta) | ||
| Pin | Name | Function |
| 1 | Vin(+) | Positive input voltage |
| 2 | ON/OFF | TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. |
| 3 | Vin(–) | Negative input voltage |
| 4 | Vout(–) | Negative output voltage |
| 5 | SENSE(–) | Return remote sense1 |
| 6 | TRIM | Output voltage trim2 |
| 7 | SENSE(+) | Positive remote sense3 |
| 8 | Vout(+) | Positive output voltage |
Half-Brick (Exa and Zeta) | ||||||||
| Pin | Name | Function | ||||||
| 1 | Vin(+) | Positive input voltage | ||||||
| 2 | ON/OFF | TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. | ||||||
| 3 | Reserved | Not connected | ||||||
| 4 | Vin(–) | Negative input voltage | ||||||
| 5 | Vout(–) | Negative output voltage | ||||||
| 6 | SENSE(–) | Return remote sense1 | ||||||
| 7 | TRIM | Output voltage trim2 | ||||||
| 8 | SENSE(+) | Positive remote sense3 | ||||||
| 9 | Vout(+) | Positive output voltage | ||||||
|
Notes: 1. SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2. Leave TRIM pin open for nominal output voltage. 3. SENSE(+) should be connected to Vout(+) either remotely or at the converter. |
||||||||