Operational Features
Safety Features
  · High efficiency at full rated load current
  · Delivers maximum output current with minimal derating
  · Wide Operating input voltage range
  · Fixed frequency switching provides predictable EMI
    performance
  · No minimum load requirement means no preload
    resistors required
  · Conduction cooled mechanical packaging
  · 2250V, 30 MW input-to-output isolation provides
    input/output ground separation
  · UL/cUL 60950-1 recognized (US & Canada), basic
    insulation rating (pending)
  · TUV certified to EN60950-1 (pending)
  · Meets 72/23/EEC and 93/68/EEC directives which
    facilitates CE Marking in user's end product
  · Board and plastic components meet UL94V-0
    flammability requirements
Protection Features
  · Input under-voltage lockout disables converter at low input voltage conditions
  · Output current limit and short circuit protection protects converter and load from permanent damage and
    consequent hazardous conditions
  · Active back bias limit prevents damage to converter from external load induced pre-bias
  · Output over-voltage protection protects load from damaging voltages
  · Thermal shutdown protects converter from abnormal environmental conditions
Mechanical Features
Control Features
  · Industry standard quarter-brick pin-out configuration
  · Industry standard size: 1.54" x 2.39" (39.0 x 60.6mm)
  · Total height less than 0.50" (12.7mm),
    permits better airflow and smaller card pitch
  · Total weight: 3.02 oz. (85.7 grams)
  · Flanged pins designed to permit surface mount
    soldering (allowing to avoid wave solder) using FPiP
    technique
  · On/Off control referenced to input side
  · Remote sense for the output voltage compensates for
    output distribution drops
  · Output voltage trim permits custom voltages and
    voltage margining