| Environmental Stress Screening |
| Screening |
Consistent with MIL-STD-883F |
C-Grade (-40ºC to +100ºC) |
ES-Grade (-55ºC to +125ºC) (Element Evaluation) |
HB-Grade (-55ºC to +125ºC) (Element Evaluation) |
| Internal Visual |
* |
Yes |
Yes |
Yes |
| Temperature Cycle |
Method 1010 |
No |
Condition B (-55ºC to +125ºC) |
Condition C (-65ºC to +150ºC) |
| Constant Acceleration |
Method 2001 (Y1 Direction) |
No |
500g |
Condition A (5000g) |
| Burn-in |
Method 1015 Load Cycled
·10s period ·2s @ 100% Load ·8s @ 0% Load |
24Hrs @+125ºC |
96Hrs @+125ºC |
160Hrs @+125ºC |
| Final Electrical Test |
Method 5005 (Group A) |
+25ºC |
-45, +25, +100ºC |
-55, +25, +125ºC |
| Mechanical Seal, Thermal, and Coating Process |
|
Full QorSeal |
Full QorSeal |
Full QorSeal |
| External Visual |
2009 |
* |
Yes |
Yes |
| Construction Process |
|
QorSeal |
QorSeal |
QorSeal |