Quarter-Brick |
|
Pin |
Name |
Function |
|
1
|
Vin(+) |
Positive input |
|
2 |
ON/OFF |
TTL input to turn converter on and off, referenced to Vin(-), with internal pull
up |
|
3
|
Vin(-) |
Negative input voltage, internal short to Pin 4 |
|
4
|
Vout(-) |
Negative output voltage, internal short to Pin 3 |
|
5 |
SENSE(-) |
Negative remote sense. See note 1 (S option) Isense (C option) |
|
6
|
TRIM |
Output voltage trim |
|
7
|
SENSE (+) |
Positive remote sense. See note 2 (S option) Isense (C option) |
|
8
|
Vout(+)
|
Positive output voltage |
Notes: 1. SENSE(-) should be connected to Vout(?) either remotely
or at the converter.
2.
SENSE(+) should be connected to Vout(+) either remotely or at the converter. |
|
Eighth-Brick |
|
Pin |
Name |
Function |
|
1
|
Vin(+)
|
Positive input voltage |
|
2
|
ON/OFF |
TTL input to turn converter on and off, referenced to Vin(-), with internal pull
up |
|
3
|
Vin(-)
|
Negative input voltage, internal short to Pin 4 |
|
4
|
Vout(-)
|
Negative output voltage, internal short to Pin 3 |
|
5 |
SENSE(-)
|
Negative remote sense1 (S option) ITRIM Current limit trim (C option) |
|
6
|
VTRIM |
Output voltage trim |
|
7 |
SENSE(+)
|
Positive remote sense2 (S option) IMON Current monitor output (C option) |
|
8 |
Vout(+)
|
Positive output voltage |
Notes: 1. SENSE(-) should be connected to Vout(?) either remotely
or at the converter.
2.
SENSE(+) should be connected to Vout(+) either remotely or at the converter. |
|
Half-Brick |
|
Pin |
Name |
Function |
|
1
|
Vin(+)
|
Positive input voltage |
|
2
|
ON/OFF |
TTL input to turn converter on and off, referenced to Vin(-), with internal pull
up |
|
A |
ITRIM |
Output current trim |
|
C |
ISHARE |
Current share |
|
3
|
Vin(-)
|
Negative input voltage, internal short to Pin 4 |
|
4
|
Vout(-)
|
Negative output voltage, internal short to Pin 3 |
|
5 |
SENSE(-)
|
Negative remote sense |
|
6
|
VTRIM |
Output voltage trim |
|
7 |
SENSE(+)
|
Positive remote sense |
|
8 |
Vout(+)
|
Positive output voltage |