| Single and Dual Output Isolated DC/DC Converters | ||
| Open-frame, single board construction for higher reliability |
PowerQor Pinouts
| Full-Brick | ||
| Pin | Name | Function |
| 1 | SyncIn | Synchronization Input (full feature versions only) |
| 2 | SyncOut | Synchronization Output (full feature versions only) |
| 3 | +ON/OFF | Turn converter on and off, referenced to – ON/OFF |
| 4 | –ON/OFF | Fully isolated ground |
| 5 | Vin(+) | Positive input voltage |
| 6 | Vin(–) | Negative input voltage |
| 7 | Vaux | Remote ON/OFF power, referenced to Vout(–) |
| 8 | IOG | Power Good or Inverted Operation Good |
| 9 | PARALLEL | Current share |
| 10 | TRIM | Output voltage trim (1) |
| 11 | SENSE(+) | Positive remote sense (2) |
| 12 | SENSE(–) | Negative remote sense (3) |
| 13 | Vout(–) | Negative output voltage |
| 14 | Vout(–) | Negative output voltage |
| 15 | Vout(–) | Negative output voltage |
| 16 | Vout(+) | Positive output voltage |
| 17 | Vout(+) | Positive output voltage |
| 18 | Vout(+) | Positive output voltage |
| Notes: 1 Leave TRIM pin open for nominal output voltage. 2 SENSE(+) should be connected to Vout(+) either remotely or at the converter. 3 SENSE(–) should be connected to Vout(–) either remotely or at the converter. |
||
| Half-Brick | ||
| Pin | Name | Function |
| 1 | Vin(+) | Positive input voltage |
| 2 | ON/OFF | TTL input to turn converter on and off, referenced to Vin(-), with internal pull up. |
| 3 | I share | Single wire parallel signal (Optional) |
| 4 | Vin(-) | Negative input voltage |
| 5 | Vout(+) | Positive output voltage |
| 6 | Vout(-) | Negative output voltage |
| 7 | SENSE(-) | Return remote sense |
| 8 | TRIM | Output voltage trim |
| 9 | SENSE(+) | Positive remote sense |
| 10 | Vout(+) | Positive output voltage |
| 11 | Vout(-) | Negative output voltage |
| A | Clock Sync | Clock synchronization (Optional) |
| B | Start Sync | Startup synchronization (Optional) |
| Quarter-Brick | ||
| Pin | Name | Function |
| 1 | Vin(+) | Positive input voltage |
| 2 | ON/OFF | TTL input to turn converter on and off, referenced to Vin(-), with internal pull up. |
| 3 | Vin(-) | Negative input voltage |
| 4 | Vout(-) | Negative output voltage |
| 5 | SENSE(-) | Negative remote sense (1) |
| 6 | TRIM | Output voltage trim (2) |
| 7 | SENSE(+) | Positive remote sense (3) |
| 8 | Vout(+) | Positive output voltage |
| Notes: 1 SENSE(-) may be connected to Vout(-) or left open. 2 Leave TRIM pin open for nominal output voltage. 3 SENSE(+) may be connected to Vout(+) or left open. |
||
| Eighth-Brick | ||
| Pin | Name | Function |
| 1 | Vin(+) | Positive input voltage |
| 2 | ON/OFF | TTL input to turn converter on and off, referenced to Vin(-), with internal pull up. |
| 3 | Vin(-) | Negative input voltage |
| 4 | Vout(-) | Negative output voltage |
| 5 | SENSE(-) | Negative remote sense (1) |
| 6 | TRIM | Output voltage trim (2) |
| 7 | SENSE(+) | Positive remote sense (3) |
| 8 | Vout(+) | Positive output voltage |
| Notes: 1 SENSE(-) may be connected to Vout(-) or left open. 2 Leave TRIM pin open for nominal output voltage. 3 SENSE(+) may be connected to Vout(+) or left open. |
||
| Quarter-Brick | ||
| Pin | Name | Function |
| 1 | Vin(+) | Positive input voltage |
| 2 | ON/OFF | TTL input to turn converter on and off, referenced to Vin(-), with internal pull up. |
| 3 | Vin(-) | Negative input voltage |
| 4 | 1.225Vout(+) | 1.225V positive output voltage |
| 5 | OP RTN | Output Return |
| 6 | TRIM | Output voltage trim |
| 7 | 2.45Vout(+) | 2.45V positive output voltage |