EN50155 Input Specifications
|
|
Nom. Input |
Input Range |
Transients |
SynQor Input Range |
| Vin |
0.7-1.25(Vin) |
0.6Vin 0.1s |
1.4Vin 1s |
Steady State |
Transient (0.1s) |
|
24V |
17-30V |
14V |
34V |
9-36V |
40V |
|
72V |
50-90V |
43V |
110V |
42-110V |
N/A |
|
110V |
77-137V |
66V
|
160V
|
66-160V |
170V |
|
Qualification Highlights |
SynQor EN50155 Qualification
-
Temperature/Relative Humidity Test
Non Biased
55°C, 95% RH
10 hours
-
Operating Temperature Test
VIN Nominal, Full Load, Continuous
85°C for 6 hours, 2 hours at -40°C
-
Electrical Test - Functional ATE Test
|
SynQor Standard Qualification
-
Life Test
- 95% line and load, 1000 hours
-
Vibration
- 10-55Hz, 0.06", 1 min/sweep, 120 sweeps for 3 axis
-
Mech. Shock
- 100G, 3 drops each axis
-
Temp Cycle
- -40°C to 100°C, 15°C/min ramp, 500 cycles
-
Power/Thermal Cycle
- Temp min to max, VIN min to max, full load, 100 cycles
-
Design Marginality
- TMIN-10°C to TMAX+10°C, 5°C steps, VIN min to max, 0 to 105% load
-
Humidity
- +85°C, 85% RH, 1k hours
-
Solderability
- MIL-STD-883, method 2003
-
Electrical Test - ATE test to post-qualification limits
|