Operational Features
• Isolated 100W output power
• Universal input frequency range: 47 - 63Hz / 360 - 800Hz
• Input voltage range: 85-264Vrms
• <1.5% THD at 115Vrms, full load
• Internal inrush current limit
• Auxiliary 10V bias supply, primary-side referenced
• Can be paralleled (droop version only)
Mechanical Features
• Industry standard Half-brick size
• Size: 2.386” x 2.486” x 0.512” (60.6 x 63.1 x 13.0 mm)
• Weight: 4.8 oz (136 g)
Compliance Features
When used with SynQor ACF-U-230-QM filter
• RTCA/DO-160G
• Airbus ABD0100.1.8
• Boeing 787B3-0147
• Boeing D6-36440
• Boeing D6-44588
Control Features
• PFC Enable
• AC Power Good Signal
• DC Power Good Signal
Safety Features
• Input to Output reinforced isolation 4250Vdc
• Input/Output to baseplate isolation 2150Vdc
• CE Marked
Protection Features
• Input current limit and auto-recovery short circuit protection
• Auto-recovery input under/over-voltage protection
• Auto-recovery over-voltage protection
• Auto-recovery thermal shutdown