Operational Features
• High efficiency, 96.7% at full rated load current
Mechanical Features
• High efficiency, 96.7% at full rated load current
• Delivers 38A full power with minimal derating - no heatsink required
• Operating input voltage range: 40-65V
• Fixed frequency switching provides predictable EMI
• No minimum load requirement
Control Features
• On/Off control referenced to input side (positive and negative logic options are available)
• Inherent current share (by droop method) for high current and parallel applications.
Safety Features
• UL 60950-1:2007/R:2011-12
• EN 60950-1:2006/A2:2013
• CAN/CSA C22.2 No. 60950-1:2007/A1:2011
Protection Features
• Input under-voltage lockout and over-voltage shutdown protects against abnormal input voltages
• Output current limit and short circuit protection (auto recovery)
• Output over-voltage protection
• Thermal shutdown