Operational Features
• Ultra-high efficiency, 95% at full rated load current
• Delivers 30A of current at (360W) full power with minimal derating - no heatsink required
• Wide operating input voltage range: 35-75V with 100V 100ms input voltage transient withstand capability
• Fixed frequency switching provides predictable EMI
Mechanical Features
• Industry standard half-brick pin-out configuration
• Size: 2.4” x 2.3” (61.0x58.4mm), height: 0.422” (10.72mm)
• Total open frame weight: 2.6 oz (75g)
Control Features
• On/Off control referenced to input side (positive and negative logic options are available)
• Remote sense for the output voltage compensates for output distribution drops
• Output voltage trim down to 6.0V permits custom voltages and voltage margining (+5%/-50%)
• Short startup inhibit time
Safety Features
• UL 60950-1/R2011-12
• EN60950-1/A2:2013
• CAN/CSA-C22.2 No. 60950-1/A1:2011
Protection Features
• Input under-voltage lockout
• Output current limit and short circuit protection
• Output over-voltage protection
• Thermal shutdown
• Backdrive protection prevents excessive negative current flow