Operational Features
• High efficiency, 85% at full rated load current
• Delivers full power with minimal derating - no heatsink required
• Operating input voltage range: 9-75V
• Fixed frequency switching provides predictable EMI
• No minimum load requirement
Mechanical Features
• Industry standard Quarter-brick pin-out configuration
• Size: 2.386" x 1.536" x 0.500" (60.60 x 39.01 x 12.70 mm)
• Total weight: 3.0 oz (85 g)
• Flanged baseplate version available
Control Features
• On/Off control referenced to input side
• Remote sense for the output voltage
• Output voltage trim range of -20%, +10%
Safety Features
• UL 60950-1/R:2011-12 Basic Insulation
• CAN/CSA-C22.2 No. 60950-1/A1:2011
• EN 60950-1/A12:2011
• RoHS compliant (see last page)
Protection Features
• Input under-voltage lockout
• Output current limit and short circuit protection
• Active back bias limit
• Output over-voltage protection
• Thermal shutdown