Operational Features
• High efficiency, 89% at full rated load current
• Operating input voltage range: 240-280 V
• Fixed frequency switching provides predictable EMI
• No minimum load requirement
Mechanical Features
• Industry standard half-brick pin-out configuration
• Size: 2.49” x 2.39” x 0.51” (63.1 x 60.6 x 13.0 mm)
• Total weight: 4.9 oz. (139 g)
• Flanged baseplate version available
Specification Compliance Features
MCOTS series converters (with an MCOTS filter) are designed to meet:
• MIL-HDBK-704 (A-F)
• RTCA/DO-160E Section 16
• MIL-STD-1275 (B,D)
• DEF-STAN 61-5 (Part 6)/(5 or 6)
• MIL-STD-461 (C, D, E)
• RTCA/DO-160E Section 22
Control Features
• On/Off control referenced to input return
• Remote sense for the output voltage
• Output voltage trim range of +10%, -10%
• Active current sharing (full feature option)
• Clock synchronization (full feature option)
• Start synchronization (full feature option)
Safety Features
• 4250V dc, 100 MΩ input-to-output isolation
• (see Standards and Qualifications page)
Protection Features
• Input under-voltage lockout
• Output current limit and short circuit protection
• Active back bias limit
• Output over-voltage protection
• Thermal shutdown