• Input voltage range: 85-264Vrms
• Universal input frequency range: 47 - 63Hz / 360 - 800Hz
• 700W output power
• ≥0.99 Power Factor
• High efficiency: >95% (230Vrms)
• Internal inrush current limit
• Auxiliary 10V bias supply
• Can be paralleled with current sharing
• Compatible with SynQor’s MCOTS DC-DC converters and SynQor’s MCOTS AC line filters
Mechanical Features
• Industry standard half-brick pin-out
• Size: 2.386” x 2.486” x 0.512” (60.6 x 63.1 x 13.0 mm)
• Total weight: 4.9 oz (139 g)
• Flanged baseplate version available
Compliance Features
Designed to meet these standards when used with
SynQor MACF Filters & MCOTS DC-DC Converters.
• MIL-STD-461(A-F)
• MIL-STD-1399
• MIL-STD-704-2, -704-4, & -704-6* (see 704 app section)
Control Features
• PFC Enable
• Load Enable (also: Power Out Good signal)
• AC Power Good Signal
• Clock synchronization
• Output current monitor / Active current sharing
Safety Features
• Input/Output to baseplate isolation 2150Vdc
• CE Marked
Protection Features
• Input current limit and auto-recovery short circuit protection
• Auto-recovery input under/over-voltage protection
• Auto-recovery output over-voltage protection
• Auto-recovery thermal shutdown