Operational Features
• Isolated output, 600W output power
• Output remains in regulation during input dropout event
• Universal input frequency range: 47 - 63Hz / 360 - 800Hz
• Input voltage range: 85-264Vrms
• ≥0.99 Power Factor
• High efficiency: 88% (230Vrms)
• Minimal inrush current
• Secondary side control pins with 3.3V standby power
• Can be paralleled (droop version only)
Mechanical Features
• Industry standard full-brick package
• Size: 2.486” x 4.686” x 0.512” (63.14 x 119.02 x 13.0 mm)
• Total weight: 11.3oz (320g)
• Flanged baseplate version available
Compliance Features
Designed to meet these standards when used with SynQor MACF Filters.
• MIL-STD-461(A-F)
• MIL-STD-1399
• MIL-STD-704-2, -704-4, & -704-6* (see 704 app section)
Control Features
• All control pins referenced to secondary side
• Asynchronous serial data interface
• AC and DC Power Good outputs
• PFC Enable and Battle Short inputs
• 3.3V standby power and clock synchronization output
Safety Features
Pending
• Input to output reinforced isolation 4250Vdc
• Input/Output to baseplate isolation 2500Vdc
• CE Marked
Protection Features
• Input current limit and auto-recovery short circuit protection
• Auto-recovery input under/over-voltage protection
• Auto-recovery over-voltage protection
• Auto-recovery thermal shutdown