Operational Features
• Input voltage range: 85 - 264 Vrms • Universal input frequency range: 47 - 63 Hz / 360 - 800 Hz • Up to 600 W output power • ≥ 0.99 Power Factor (50/60 Hz) • Internal inrush current limit • Hold-Up Capacitors (with available external connection)
Mechanical Features
• Size: 6.70” x 9.12” x 1.23” (170.2 x 231.6 x 31.3 mm) • Refer to mechanical diagrams for weight • Cold plate with mounting holes for connection to heat removal system
Compliance Features
Designed to meet these standards: • MIL-STD-461 ▪ CE101 ▪ CE102 ▪ RE101 ▪ RE102 ▪ CS101 ▪ CS106 ▪ CS114 ▪ CS115 ▪ CS116 • MIL-STD-1399 • MIL-STD-704-2, -704-4, & -704-6* (see 704 app section)
Control Features
• PFC Enable (isolated) • Individual output voltage Enable control (isolated) • AC Power Good Signal (isolated)
Safety Features
• Input/Output to baseplate isolation 2150 Vdc • Internal input fuses
Protection Features
• Input current limit and auto-recovery short circuit protection • Auto-recovery input under/over-voltage protection • Auto-recovery output over-voltage protection • Auto-recovery thermal shutdown