Operational Features
♦ Designed to comply with MIL-STD-704 (A - F) Steady State
♦ High efficiency converters (90%-95%)
♦ Fixed frequency switching provides predictable EMI
♦ No minimum load requirement
♦ Soft start of all outputs
Mechanical Features
♦ Multiple physical formats
- P1: 3.80” x 6.90” x 0.97” (Single output)
- P2: 3.80” x 6.90” x 0.97” (Single output)
- P3: 6.70” x 6.93” x 0.97” (Single output)
♦ Refer to mechanical diagrams for weight
♦ Cold plate with mounting holes for connection to heat removal system
♦ Cover
Control Features
♦ System On/Off control (isolated)
♦ Output voltage Inhibit control (isolated)
♦ Remote Sense for the output voltage
♦ Output voltage trim available
♦ Input Good signal (isolated)
Safety Features
♦ 1500Vdc @ 30 MΩ input-to-output isolation
♦ Internal input fuse
Protection Features
♦ Input under-voltage lockout
♦ Output current limit and short circuit protection
♦ Output over-voltage protection
♦ Thermal shutdown
♦ Automatic restart for all of the above
♦ Active back bias current limit
Options
♦ Remote Sense Jumpers
♦ Output current sharing