Operational Features
♦ Internal EMI filter with ceramic stabilizing bulk capacitor
♦ Over-voltage Spike & Surge suppression circuitry to comply with:
- MIL-STD-704 (A - F)
- MIL-STD-1275 (B,D)
- DEF-STAN 61-5 (Part 6)/(5 or 6)
♦ Reverse polarity protection
♦ High efficiency converters
♦ Fixed frequency switching provides predictable EMI
♦ No minimum load requirement
♦ Soft start of all outputs
Mechanical Features
♦ Multiple physical formats
- P1: 3.80” x 6.84” x 0.92” (Single output)
- P2: 3.80” x 6.84” x 0.92” (Dual output)
- P3: 6.70” x 6.84” x 0.92” (Triple output)
- P4: 6.70” x 6.84” x 0.92” (Quad output)
♦ Refer to mechanical diagrams for weight
♦ Cold plate with mounting holes for connection to heat removal system
Control Features
♦ System On/Off control (isolated)
♦ Individual output voltage Inhibit control (isolated)
♦ Remote Sense for each output voltage
♦ Output voltage trim (-20%, +10%) for each output
♦ Input Good signal (isolated)
Safety Features
♦ 1500Vdc @ 30 MΩ input-to-output isolation
♦ Internal input fuse (optional)
Protection Features
♦ Input under-voltage lockout
♦ Output current limit and short circuit protection
♦ Output over-voltage protection
♦ Thermal shutdown
♦ Automatic restart for all of the above
♦ Active back bias current limit
Options
♦ Remote Sense Jumpers
♦ Internal input fuse
♦ Cover