Operational Features
• High efficiency, 90% at full rated load current
• Delivers up to 8.33A of output current (100W) with minimal derating
- no heatsink required
• Ultra wide input voltage range: 18V – 75V, with 100V 100ms input voltage transient capability
• Fixed frequency switching provides predictable EMI performance
• No minimum load requirement means no preload resistors required.
Mechanical Features
• Industry standard pin-out configuration
• Standard Size: 2.30"x1.45"x0.397" (58.4x36.8x10.08mm)
• Weight: 1.2 oz. (34 grams)
• Flanged pins designed to permit surface mount soldering, avoid wave solder using FPiP technique on open frame units
Control Features
• On/Off control referenced to input side (positive and negative logic options are available)
• Remote sense for the output voltage compensates for output distribution drops
• Output voltage trim permits custom voltages and voltage margining
Safety Features
• CAN/CSA C22.2 No. 60950-1
• UL 60950-1
• EN 60950-
Protection Features
• Input under-voltage lockout disables converter at low input voltage
• Output current limit and short circuit protection protects converter from excessive load current or short circuits
• Active back bias limit prevents damage to converter from external load induced pre-bias
• Output over-voltage protection protects load from damaging voltages
• Thermal shutdown protectsconverer from abnormal environmental conditions