Operational Features
• High efficiency, up to 82% at 1.0Vout
• Delivers up to 15 amps of output current with minimal derating - no heatsink required
• Wide input voltage range: 35V – 75V, with 100V 100ms input voltage transient capability
• Fixed frequency switching provides predictable EMI performance
• No minimum load requirement means no preload resistors required
Mechanical Features
• Industry standard eighth-brick pin-out configuration
• Industry standard size: 0.90” x 2.3” (22.9x58.4mm)
• Total height only 0.335” (8.5mm), permits better airflow and smaller card pitch
• Total weight: 0.68 oz. (19 grams)
• Flanged pins designed to permit surface mount soldering (avoid wave solder) using FPiP technique
Control Features
• On/Off control referenced to input side (positive and negative logic options are available)
• Remote sense for the output voltage compensates for output distribution drops
• Output voltage trim permits custom voltages and voltage margining
Safety Features
• 2000V, 30 MW input-to-output isolation provides input/output ground separation
• UL 60950-1 recognized (US & Canada), basic insulation rating
• TUV certified to EN60950-1
• Meets 72/23/EEC and 93/68/EEC directives which facilitates CE Marking in user’s end product
• Board and plastic components meet UL94V-0 flammability requirements
Protection Features
• Input under-voltage lockout disables converter at low input voltage conditions
• Output current limit and short circuit protection protects converter and load from permanent damage and consequent
hazardous conditions
• Active back bias limit prevents damage to converter from external load induced pre-bias
• Output over-voltage protection protects load from damaging voltages
• Thermal shutdown protects converter from abnormal environmental conditions