Operational Features
• Ultra-high efficiency, 86% half load, 83% full load
• Delivers up to 60 amps of output current with minimal derating - no heatsink required
• Wide input voltage range: 36V – 75V, with 100V 100ms input voltage transient capability
• Fixed frequency switching provides predictable EMI performance
• No minimum load
Mechanical Features
• Industry standard quarter-brick pin-out configuration
• Industry standard size: 1.45” x 2.3” (36.8x58.4mm)
• Total height less than 0.45” (11.4mm), permits better airflow and smaller card pitch
• Total weight: 1.5 oz. (42 grams)
• Flanged pins designed to permit surface mount soldering (avoid wave solder) using FPiP technique
Control Features
• On/Off control referenced to input side (positive and negative logic options are available)
• Remote sense for the output voltage compensates for output distribution drops
• Output voltage trim permits custom voltages and voltage margining
Safety Features
• UL 60950-1:R2011-12
• EN60950-1/A12:2011
• CAN/CSA-C22.2 No. 60950-1/A1:2011
Protection Features
• Input under-voltage lockout disables converter at low input voltage conditions
• Output current limit and short circuit protection protects converter and load from permanent damage and consequent hazardous conditions
• Active back bias limit prevents damage to converter from external load induced pre-bias
• Output over-voltage protection protects load from damaging voltages
• Thermal shutdown protects converter from abnormal environmental conditions