Operational Features
►High efficiency, 88% at full rated load current
►Delivers full power with minimal derating - no heatsink required
►Operating input voltage range: 66-160V
►Fixed frequency switching provides predictable EMI
►No minimum load requirement
►Meets requirements of standard EN 50155
Mechanical Features
►Industry standard half-brick pin-out configuration
►Size: 2.386" × 2.486" × 0.512", (60.6 × 63.14 × 13.00 mm)
►Total weight: 5.0 oz (142 g)
►Flanged baseplate version available
Control Features
►On/Off control referenced to input side
►Remote sense for the output voltage
►Output voltage trim range of -20%, +10%
Safety Features
PENDING
► Input-to-output isolation 3000V
► UL 60950-1
► CAN/CSA C22.2 No. 60950-1
► EN 60950-1
► CE Marked
► RoHS compliant (see last page)
Protection Features
►Input under-voltage lockout
►Output current limit and short circuit protection
►Active back bias limit
►Output over-voltage protection
►Thermal shutdown