Operational Features
• High efficiency, 95% at full rated load current
• Operating input voltage range: 16-40 V
• Fixed frequency switching provides predictable EMI
• No minimum load requirement
Mechanical Features
• Industry standard full-brick form factor
• Size: 4.686” x 2.486” x .512” 119.0 x 63.1 x 13.0 mm
• Total weight: 9.9 oz (280 g)
• Flanged baseplate version available
Specification Compliance Features
MCOTS series converters (with an MCOTS filter) are designed to meet:
• MIL-HDBK-704 (A-F)
• RTCA/DO-160E Section 16
• MIL-STD-1275 (B,D)
• DEF-STAN 61-5 (Part 6)/(5 or 6)
• MIL-STD-461 (C, D, E, F)
Control Features
• Fully isolated On/Off control
• Fully isolated active current sharing
Safety Features
• 3000V dc, 100 MΩ input-to-output isolation - pending
• (see Standards and Qualifications page)
Protection Features
• Input under-voltage lockout
• Output current limit and short circuit protection
• Active back bias limit
• Auto-recovery output over-voltage protection
• Thermal shutdown